General Introduction
Tokyo Keiso TLR7400 level meter is a non-contact type continuous level meter using microwaves. This meter determines the level of a measured object by emitting microwaves and measuring the time taken for the microwaves to travel out, be reflected and return from the object. Since the velocity of electromagnetic waves is hardly affected by temperature and pressure, meters of this type can accurately measure levels under any conditions. Measurements are also independent of the viscosity, or changes in the density and temperature of measured objects, allowing such meters to be used for a wide range of temperatures and pressures. The 2-wire transmission system enables high-accuracy and low-cost level measurement. Inheriting the features of existing microwave level meters, the TLR7400 is even easier to use. And its features list as follows:
-Non-contact, continuous level measurement
-Low total cost achieved by 2-wire system
-Measuring various objects such as liquids and slurries
-Displaying and outputting measurements as level, ullage, volume, and mass
-PTFE drop antennas assuring high corrosion resistance
-PEEK drop antennas operable at up to 200ºC
-Wide operation range: -50ºC to 200ºC and vacuum to 4 MPa
-High-accuracy level measurement independent of changes in temperature, pressure, or density
-Easy mounting on top of tanks
-Simple mounting thanks to the compact housing design
-Quick start with simple parameter setting
-Quick start with interactive parameter setting
-Maintenance-free with no moving parts
2. Short Specifications
Model
|
TLR7400
|
Measurable materials
|
Liquids, paste and Slurries
|
Measuring range
|
Max.100m
|
Temperature
|
Process connection: -50 to 200 ºC
Ambient: -40 to 80 ºC
|
Pressure
|
0 kPa (abs) to 4.0 MPa
|
Process connection
|
Thread: G1-1/2, 1-1/2”NPT male thread
Flange: JIS 10K 40 to 200A
ASME 1-1/2” to 8” 150 lbs,300 lbs
|
Material
|
Stainless steel(SUS316L), PTFE, PEEK
|
Power supply
|
24V DC
|
Output type
|
Level, Distance, Capacity and mass
|
Antenna type
|
Metal horn, Drop
|
3. Basic Code Selection of TLR7400 With Metal Horn Antenna
Main
Code
|
Suffix Codes
|
Description
|
VFDE44W
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Always VFDE44W
|
Approval
|
0
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard (Non-ex)
|
1
|
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Ⅱ1/2G Ex ia ⅡC T6…T3 Ga/Gb
|
2
|
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Ⅱ1/2G Ex db ia ⅡC T6…T3 Ga/Gb
|
K
|
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Ex ia ⅡC T6…T3 Ga/Gb
|
L
|
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Ex db ia ⅡC T6…T3 Ga/Gb
|
Fixed code
|
|
0
|
|
|
|
|
|
|
|
|
|
|
|
Always 0
|
Approval 2
|
|
|
0
|
|
|
|
|
|
|
|
|
|
|
N/A
|
|
|
3
|
|
|
|
|
|
|
|
|
|
|
NACE(MR0175 / MR0103 / ISO15156)
|
Housing Type/material
|
|
|
|
2
|
|
|
|
|
|
|
|
|
|
Compact type housing(aluminum)
|
Output
|
|
|
|
|
1
|
|
|
|
|
|
|
|
|
Two-wire system/4-20mA passive(HART)
|
Process connection
|
|
|
|
|
|
1
|
|
|
|
|
|
|
|
1-1/2 inch flange
|
|
|
|
|
|
2
|
|
|
|
|
|
|
|
2 inch flange
|
|
|
|
|
|
3
|
|
|
|
|
|
|
|
3, 4 inch flage (used only for the installation '5'top mount)
|
|
|
|
|
|
9
|
|
|
|
|
|
|
|
Special
|
Cable entry/ cable gland
|
|
|
|
|
|
|
1
|
|
|
|
|
|
|
M20×1.5/Without cable gland
|
|
|
|
|
|
|
2
|
|
|
|
|
|
|
M20×1.5/With a plastic cable gland
|
|
|
|
|
|
|
3
|
|
|
|
|
|
|
M20×1.5/With a metal cable gland
|
|
|
|
|
|
|
C
|
|
|
|
|
|
|
1/2 NPT/Without cable gland
|
Display
|
|
|
|
|
|
|
|
0
|
|
|
|
|
|
Without display unit
|
|
|
|
|
|
|
|
4
|
|
|
|
|
|
With a plug-in display unit
|
Display language
|
|
|
|
|
|
|
|
|
0
|
|
|
|
|
Without display
|
|
|
|
|
|
|
|
|
1
|
|
|
|
|
English
|
|
|
|
|
|
|
|
|
7
|
|
|
|
|
Japanese
|
Fixed code
|
|
|
|
|
|
|
|
|
|
0
|
|
|
|
Always 0
|
Seal material/temperature range
|
|
|
|
|
|
|
|
|
|
|
1
|
|
|
FKM/FPW/-40 to 200ºC
|
|
|
|
|
|
|
|
|
|
|
2
|
|
|
EPDM/-50 to 150ºC
|
|
|
|
|
|
|
|
|
|
|
3
|
|
|
Kalrez6375/-20 to 200ºC
|
Antenna type
|
|
|
|
|
|
|
|
|
|
|
|
1
|
|
DN40 Metal horn antenna (∅39mm)
|
|
|
|
|
|
|
|
|
|
|
|
2
|
|
DN50 Metal horn antenna (∅43mm)
|
|
|
|
|
|
|
|
|
|
|
|
4
|
|
DN80 Metal horn antenna (∅75mm)
|
|
|
|
|
|
|
|
|
|
|
|
5
|
|
DN100 Metal horn antenna (∅95mm)
|
|
|
|
|
|
|
|
|
|
|
|
6
|
|
DN150 Metal horn antenna (∅140mm)
|
|
|
|
|
|
|
|
|
|
|
|
7
|
|
DN200 Metal horn antenna (∅190mm)
|
Antenna extension
|
|
|
|
|
|
|
|
|
|
|
|
|
0
|
None
|
|
|
|
|
|
|
|
|
|
|
|
|
1
|
105mm
|
|
|
|
|
|
|
|
|
|
|
|
|
2
|
210mm
|
|
|
|
|
|
|
|
|
|
|
|
|
3
|
315mm
|
|
|
|
|
|
|
|
|
|
|
|
|
4
|
420mm
|
|
|
|
|
|
|
|
|
|
|
|
|
5
|
525mm
|
|
|
|
|
|
|
|
|
|
|
|
|
6
|
630mm(only for metal horn antennas)
|
|
|
|
|
|
|
|
|
|
|
|
|
7
|
735mm(only for metal horn antennas)
|
|
|
|
|
|
|
|
|
|
|
|
|
8
|
840mm(only for metal horn antennas)
|
|
|
|
|
|
|
|
|
|
|
|
|
A
|
945mm(only for metal horn antennas)
|
|
|
|
|
|
|
|
|
|
|
|
|
B
|
1050mm(only for metal horn antennas)
|
4. Basic Code Selection of TLR7400 With Drop Horn Antenna
Main
Code
|
Suffix Codes
|
Description
|
VFDE44W
|
|
|
|
|
|
|
|
|
|
|
|
|
Always VFDE44W
|
Approval
|
0
|
|
|
|
|
|
|
|
|
|
|
|
Standard (Non-ex)
|
1
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Ⅱ1/2G Ex ia ⅡC T6…T3 Ga/Gb
|
2
|
|
|
|
|
|
|
|
|
|
|
|
ATEX Ⅱ1/2G Ex db ia ⅡC T6…T3 Ga/Gb
|
K
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Ex ia ⅡC T6…T3 Ga/Gb
|
L
|
|
|
|
|
|
|
|
|
|
|
|
IECEx Ex db ia ⅡC T6…T3 Ga/Gb
|
Fixed code
|
|
0
|
|
|
|
|
|
|
|
|
|
|
Always 0
|
Approval 2
|
|
|
0
|
|
|
|
|
|
|
|
|
|
N/A
|
|
|
3
|
|
|
|
|
|
|
|
|
|
NACE(MR0175 / MR0103 / ISO15156)
|
Housing Type/material
|
|
|
|
2
|
|
|
|
|
|
|
|
|
Compact type housing(aluminum)
|
Output
|
|
|
|
|
1
|
|
|
|
|
|
|
|
Two-wire system/4-20mA passive(HART)
|
Cable entry/ cable gland
|
|
|
|
|
|
1
|
|
|
|
|
|
|
M20×1.5/Without cable gland
|
|
|
|
|
|
2
|
|
|
|
|
|
|
M20×1.5/With a plastic cable gland
|
|
|
|
|
|
3
|
|
|
|
|
|
|
M20×1.5/With a metal cable gland
|
|
|
|
|
|
C
|
|
|
|
|
|
|
1/2 NPT/Without cable gland
|
Display
|
|
|
|
|
|
|
0
|
|
|
|
|
|
Without display unit
|
|
|
|
|
|
|
4
|
|
|
|
|
|
With a plug-in display unit
|
Display language
|
|
|
|
|
|
|
|
0
|
|
|
|
|
Without display
|
|
|
|
|
|
|
|
1
|
|
|
|
|
English
|
|
|
|
|
|
|
|
7
|
|
|
|
|
Japanese
|
Fixed code
|
|
|
|
|
|
|
|
|
0
|
|
|
|
Always 0
|
Seal material/temperature range
/pressure range
|
|
|
|
|
|
|
|
|
|
1
|
|
|
FKM/FPW/-40 to 200ºC/0kpa(abs) to 4Mpa
|
|
|
|
|
|
|
|
|
|
2
|
|
|
EPDM/-50 to 150ºC/0kpa(abs) to 4Mpa
|
|
|
|
|
|
|
|
|
|
3
|
|
|
Kalrez6375/-20 to 200ºC/0kpa(abs) to 4Mpa
|
Antenna type
|
|
|
|
|
|
|
|
|
|
|
E
|
|
DN80 PTFE Drop antenna (∅74mm) Max.150ºC
|
|
|
|
|
|
|
|
|
|
|
F
|
|
DN100 PTFE Drop antenna (∅94mm) Max.150ºC
|
|
|
|
|
|
|
|
|
|
|
G
|
|
DN150 PTFE Drop antenna (∅144mm) Max.150ºC
|
|
|
|
|
|
|
|
|
|
|
K
|
|
DN80 PTFE Drop antenna (∅74mm) Max.200ºC
|
Antenna extension
|
|
|
|
|
|
|
|
|
|
|
|
0
|
None
|
|
|
|
|
|
|
|
|
|
|
|
1
|
105mm
|
|
|
|
|
|
|
|
|
|
|
|
2
|
210mm
|
|
|
|
|
|
|
|
|
|
|
|
3
|
315mm
|
|
|
|
|
|
|
|
|
|
|
|
4
|
420mm
|
|
|
|
|
|
|
|
|
|
|
|
5
|
525mm
|
|
|
|
|
|
|
|
|
|
|
|
D
|
PTFE flange plate(only for PTFE drop antennas)
|